【Voltage Compatibility】
Our products are selected to support international voltage ranges (e.g. 100–240V).
However, please make sure your local voltage is compatible before use, as incorrect voltage may still cause malfunction.
【Plug Type】
Our products use Japanese plug types (A or B type).
Please use a conversion adapter if necessary.
【Important Note on Transformers and Adapters】
A transformer adjusts voltage to match your device’s requirements.
A conversion adapter only changes the plug shape and does not adjust voltage.
Using only a conversion adapter without a transformer may result in damage to the product.
【Liability】
We are not responsible for malfunctions or damages caused by improper use, such as operating the product without appropriate voltage or equipment.
---------------------------------------------------
1. High performance - Measures gamma rays (γ-rays) using a high-performance, compact scintillator system.
2. High quality - All processes from development to production are carried out in Japan.
3. PC Link: Simply place the device on the FeliCa port for easy communication.
4. User-Friendly - Approximately 62g (excluding batteries), the lightest class of all-in-one devices made in Japan. (According to our research)
5. Accumulative measurement possible - Radiation levels can be accumulated for up to 9,999 hours (approximately 416 days) and managed on a daily, weekly, monthly or yearly basis.
This is a high-quality, highly accurate radiation monitor that has been developed and produced entirely in Japan by a manufacturer specializing in medical and other measuring instruments. Sales name RADCOUNTER (air dosimeter) Model DC-200 Measurement method CsI (Tl) scintillator + photodiode method Measurement target γ (gamma) rays Measurement range Dose (1cm dose equivalent rate) 0.001μSv/h to 19.99μSv/h Blinks when 19.99μSv/h or more Accumulated dose 0.000μSv to 999.9mSv Accumulation time 0:00 Hour to 9999 Hour Measurement accuracy ±15% (minimum error: 0.01μSv/h) Response time 20 seconds Display time when power is turned ON Automatic response to dose after measurement value is displayed Directional characteristics Within ±20% in both horizontal and vertical directions relative to the detector axis Buzzer sound Synchronized with radiation (γ rays) When the buzzer setting is ON Continuous sound (default value is 3.8μSv/h or more) Regardless of buzzer setting Low battery indicator Low battery indicator flashes Approx. 2.1 to 1.9V Low battery indicator lights up Approx. 1.9V or less (stops operation) Protection against water ingress IPX1 (water-resistant) Electromagnetic compatibility IEC60601-1-2:2001 IEC61326-1:
2005 Power supply AAA alkaline batteries or 2 AAA nickel-hydrogen rechargeable batteries Battery life When using new alkaline batteries, approximately 100 days with 30 minutes of use per day (battery life may be shortened when the buzzer is set to ON or when measuring high doses) Battery life varies depending on the manufacturer and conditions of use Power consumption 50mW (average) Operating temperature and humidity / storage temperature and humidity -10℃ to +50℃, 85% RH or less / -20℃ to +60℃, 85% RH or less (no condensation) Dimensions Approximately 60mm (W) x 85mm (D) x 22mm (H) Weight Approximately 62g (excluding batteries) Manufacturer's information site http://www.nissei-kk.co.jp/html/dc200.html