・Thin, light, compact design for easy portability
・Can clamp cables with a finished outer diameter of φ35 mm or less
・Supports AC and DC current measurement, equipped with AC/DC 1000 A range
・True RMS (true root mean square) suitable for measurements in noisy environments such as around inverter-using equipment
・Supports CAT III 600 V (when measuring current) and CAT III 300 V (when measuring voltage) as specified by safety standards
[Measurement items]
AC current: Yes, DC current: Yes, AC+DC current: No, AC voltage: Yes, DC voltage: Yes, AC+DC voltage: No,
AC power: No, DC power: No, Resistance: Yes, Temperature: No, Capacitance: No, Frequency: No, Continuity check: Yes, Diode check: No
- AC current (range): 100.0 A/1000 A, (specified accuracy range): 1.0 A to 1000 A, (representative accuracy): ±1.5% rdg ±5 dgt
- DC current (range) 100.0 A/1000 A, (specified accuracy range) 1.0 A to 1000 A, (typical accuracy) ±1.5% rdg ±5 dgt
- AC voltage (range) 4.200 V/42.00 V/420.0 V/600 V, (specified accuracy range) 0.400 V to 600 V, (typical accuracy) ±2.3% rdg ±8 dgt
- DC voltage (range) 420.0 mV/4.200 V/42.00 V/420.0 V/600 V, (specified accuracy range) 40.0 mV to 600 V, (typical accuracy) ±1.3% rdg ±4 dgt
- Resistance (range) 420.0 Ω/4.200 kΩ/42.00 kΩ/420.0 kΩ/4.200 MΩ/42.00 MΩ, (specified accuracy range) 40.0 Ω to 41.99 MΩ, (representative accuracy) ±2.0% rdg ±4 dgt
[Features]
AC/DC automatic discrimination (current/voltage) ×, Display of maximum/minimum/average value of measurement value (effective value) ×, Display of maximum/minimum value of peak value (PEAK value) ×, Display of effective value of inrush current ×,
Backlight ×, AUTO power save ○, AUTO range switching ○, Display value hold (manual) ○
[Power supply]
1 coin-type lithium battery (CR2032)
[Continuous use time]
Approx. 35 hours
[External dimensions/weight]
Approx. 57W × 180H × 16D mm, approx. 150 g
[Accessories]
L9208 test lead, 9398 Carrying Case, Coin-type Lithium Battery (CR2032), Instruction Manual
[Options]
- 9209 Test Lead Holder
- L4933 Contact Pin (Can be connected to the tip of the included L9208. When installing, remove the cap before installing)
- L4934 Small Alligator Clip (Can be connected to the tip of the included L9208. When installing, remove the cap before installing)
[Country of Origin]
Japan
[Please note] If the shipper/seller is not "Amazon.co.jp", the instruction manual in Japanese may not be included.
Thin, light, and compact for easy carrying
Can clamp cables with a finished outer diameter of φ35 mm or less
Supports AC and DC current measurement, equipped with AC/DC 1000 A range
True RMS (true root mean square) suitable for measurements in noisy environments such as around inverter-using equipment